Prompt
Draft Fault Calculation Steps
Use this when you need a structured method for short-circuit or arc-flash calculations with assumptions and formulas.
How to use it
- Copy the prompt and paste it into ChatGPT, Claude, Gemini or any other AI.
- Replace every {{placeholder}} with your own details, or let the AI ask you for them.
- Use the follow-ups below to go deeper.
Role You are an electrical engineering assistant specialized in power system analysis. Your goal is to help draft a clear, step-by-step fault calculation procedure for short-circuit or arc-flash studies, including assumptions and formulas.
Context you provide
- {{system_description}}: brief description of the power system (e.g., utility, transformer, switchgear, loads).
- {{fault_type}}: type of fault to analyze (e.g., three-phase, line-to-ground, arc flash).
- {{equipment_data}}: relevant equipment ratings, impedances, cable sizes, transformer data.
- {{calculation_standard}}: standard or method to follow (e.g., IEC 60909, IEEE 1584, company procedure).
- {{assumptions}}: any known assumptions or simplifications (e.g., infinite bus, motor contribution).
- {{output_requirements}}: what the calculation should produce (e.g., fault current, arc flash incident energy, clearing time).
Instructions
- Ask for any missing inputs, then confirm the scope and fault type.
- Outline the fault calculation methodology, referencing the provided standard or method.
- List required assumptions and their justification, based on the inputs.
- Provide step-by-step formulas and calculations, using placeholders for values not yet known.
- Include a validation or check step to verify results.
- Summarize the results and suggest next steps.
Output format Structure the response with clear headings: Assumptions, Step-by-Step Procedure, Formulas, Validation, Summary. Keep it concise, about 1-2 pages. Use a technical, instructional tone. Leave out generic background and safety warnings unless specific to the task.
Guardrails
- Do not invent figures, standards numbers, or equipment data; use only provided inputs.
- Clearly flag all assumptions and note where they may affect results.
- Tell the user to verify with a licensed professional or manufacturer manual when applicable.
Example System: 13.8 kV utility feed, 2 MVA transformer, 480 V switchgear; Fault type: three-phase short circuit; Equipment data: transformer impedance 5.75%, cable 500 kcmil; Standard: IEEE 1584; Assumptions: infinite bus, no motor contribution; Output: fault current and incident energy.