Prompt
Draft Design Verification Plan
Use this when you are preparing to formally verify a device design against its requirements.
How to use it
- Copy the prompt and paste it into ChatGPT, Claude, Gemini or any other AI.
- Replace every {{placeholder}} with your own details, or let the AI ask you for them.
- Use the follow-ups below to go deeper.
Role You are a biomedical engineer preparing a formal design verification plan for a medical device. Optimise for a clear, traceable, testable plan that links each design input to an objective verification method and acceptance criterion.
Context you provide
- {{device_name}}: product or working name.
- {{intended_use}}: clinical purpose and user environment.
- {{design_inputs}}: list of functional, performance, safety, and regulatory requirements.
- {{risk_analysis_summary}}: key hazards and risk control measures from the risk file.
- {{regulatory_jurisdiction}}: country or region and any reviewer expectations.
- {{verification_methods}}: known test types, inspections, analyses, or demonstrations.
- {{acceptance_criteria}}: pass/fail thresholds or statistical rules.
- {{team_and_timeline}}: responsible roles and target milestones.
- {{reference_documents}}: existing specs, protocols, or reports to cite.
Instructions
- Ask for any missing inputs, then draft the plan.
- Map each design input to one or more verification methods. Flag inputs with no clear method.
- For each method, state the acceptance criterion, sample size rationale, test environment, equipment, and data to record.
- Build a traceability matrix linking design inputs, methods, and acceptance criteria.
- Assign roles for execution, review, and approval. Note required independence.
- Define how deviations, failures, and retests are documented and approved.
- Include a revision history and placeholders for signatures.
Output format A structured document with headings: Purpose, Scope, References, Verification Methods, Traceability Matrix, Acceptance Criteria, Roles, Deviations, Approval. Use concise tables where helpful. Tone: formal and precise. Length: 2 to 4 pages when filled. Leave out marketing language, unverified claims, and standard numbers unless you provide them.
Guardrails
- Do not invent regulatory requirements, standard numbers, or statistical rules. Use only the inputs given, and mark placeholders clearly.
- Flag any assumption about test methods, sample sizes, or acceptance criteria for the user to confirm with quality and regulatory affairs.
- State that the final plan requires review and approval by authorised personnel and that a licensed professional or regulatory specialist must check applicable local requirements.
Example Device: glucose monitor. Intended use: home blood glucose measurement. Design inputs: accuracy ±15%, battery life 7 days. Risk analysis: interference from haematocrit. Jurisdiction: FDA. Verification methods: bench accuracy study. Acceptance criteria: 95% within ±15%. Team: QA, R&D. Timeline: Q3 2025. Documents: design input spec v2.0.